Isolation Transformer
|
|
NEW GOLD Isolation and Ultra Transformer,
Control Transformer, Auto Transformer (Single
Phase Isolation Transformer, Two Phase Isolation
Transformer and Three Phase Isolation
Transformer).
This Isolation Transformer can also be developed
into Setup & Step down. The voltage range is 10
V to 5000 volt, and frequency 25 Hz (General use
50 Hz and 60Hz.)
Servo voltage stabilizer gives perfectly stable
output supply even under server condition of
unbalanced Voltage.
It is a available to suit the input voltage
variations of individual customers. |
|
|
|
| |
CARE DESCRIPTION OF
MACHINE AND INSTRUMENT :-
|
|
|
|
Switching
of electrical utilities in industrial and commercial
environment generates spikes up to 6000 Volt & high
frequency power line noise. The high frequency noises can
interfere with Digitial-Electronic equipment causing data
corruption, erratic behavior, loss of memory etc. The
noise cut-off transformer eliminates such noises and
attenuates the spikes to negligible values, providing
complete protection against such electrical disturbances. |
|
|
|
|
Application :
|
|
- Protect the CNC Machines,
Computer and Telecommunications equipment from damage due
to electrical noise, spikes etc. |
|
- Where ground potential of
system units are different from each other and are exposed
to the effects of instability at high |
|
frequencies. |
|
- Where ground of the
equipment cannot be earthed. |
|
- When no slightest current
leakage is permitted in the equipment. |
|
- Especially for computers an
CNC controls where only less then 100 micro Amps is only
permitted. |
|
- To protect against strong
lighting, impulse noise, bus short-circuit, accidental
discharge of capacitors etc. When no slightest |
|
current leakage is
permitted in the equipment. |
|
|
|
|
|
TECHNICAL
SPECIFICATION :- |
|
- System Connections
Voltage design as per customer require voltage 10
volt to 5000 volt in single phase and three phase
Design for frequency 25 Hz to 5000 Hz (General use
47 Hz to 60 Hz) ? |
-
Delta/Star, Star/Delata, Star/Star (and in Single
phase Series and panel connection) |
|
- Ratios |
1:1 and 2:1 (or as per
customer requirement) |
|
- Regulation
|
Better than 3.5%
|
|
- Di-electric strength |
2500VAC for 120Sec
|
|
- Insulation Resistance |
More than1000 Mega Ohms.
|
|
- Coupling Capacitance |
0.1 PF for 100db
|
|
- Leakage Current |
Less than 20 Micro Amps. |
|
- Common Model
Attenuation |
100db |
|
- Construction Standards |
As per IS 2026 part I
and II |
|
|
|
Our Products
Range
|
|
|
|